Customised Manual Slide Table Displacement Solutions

Manual displacement solutions are customised according to the direction of movement, travel, load and mounting configuration. Customising a manual slide table is not simply a matter of altering the platform dimensions; for machine vision, optical system assembly, sample positioning and equipment adjustment, it is necessary to take into account the number of axes of motion, effective travel, platform dimensions, load capacity, guide mechanisms, drive method, minimum resolution, mounting orientation and the overall structure resulting from the combination of multiple axes.

Step 1

Confirmation of direction of movement

Start by identifying the actual direction of adjustment, rather than selecting an XYZ slide straight away. First, determine whether the object to be adjusted is a camera, a telecentric lens, a light source, a workpiece, a fixture or some other optical component, and clarify the direction that actually needs to be adjusted.

If all that is required is ‘horizontal position + height adjustment ’, there is no need to u se an XYZ θ structure directly simply to increase the number of axes.
Step 2

Calculating the travel distance

Once the axes of motion have been determined, it is necessary to establish the actual amount of travel required in each direction.

Custom Dimensional Criteria Form

When placing a custom order, please confirm the following:

X Travel X Travel =      mm
Y Travel Y Travel =      mm
Z Travel Z Travel =      mm
θ Rotation θ Rotation =      °
Step 3

Platform size compatibility

The dimensions of the platform should not be selected based solely on the load; the following factors must also be taken into account: the base dimensions of the component to be mounted, the mounting hole positions, the stroke, and the space required for adjacent mechanisms.

If a larger telecentric lens mount is being installed, one should not simply opt for a 40 mm platform just because the load is only 2 kg.

You must also check:

  • 1. Whether the mounting holes match; verify pitch, thread metric/imperial dimensions, and counterbore clearances.
  • 2. Whether the component protrudes too far beyond the platform; overhung spans amplify angular deflection and induce moment loads.
  • 3. Whether the centre of gravity is significantly offset from the centre of the platform; asymmetrical loads cause guide rail skew and premature wear.
  • 4. Whether there is any interference with the lens, light source or frame during movement. Check full envelope translation limits.

Custom Engineering Parameters

5. Custom specifications:

Table Size: L × W mm

Mounting Holes: To be confirmed according to the equipment installation diagram

Step 4

Load and Installation Assessment

Loads cannot be assessed in isolation from the centre of gravity, bending moments and the direction of installation. When the same slide is installed horizontally as opposed to vertically, the effect of gravity on the guide rails and drive mechanism differs. In particular, for XYZ stacked configurations or Z-axis cantilever structures, it is necessary to further assess the total weight and centre of gravity of the upper slide, fixtures, camera, lens and workpiece.

Load and Installation Assessment-2
Step 5

Selection of Guideways and Drive Systems

Select the appropriate guideway and drive system based on the load, stroke, required precision of adjustment, direction of movement and method of operation. Different configurations have different priorities: where highly precise positional adjustment is required, consider a cross-roller bearing combined with a differential gear or a dovetail groove combined with a precision lead screw; where handwheel operation and convenient positional movement are required, consider a dovetail groove combined with a rack-and-pinion system;

Selection of Guideways and Drive Systems
Step 6

Confirmation of Adjustment Capabilities

The customisation requirements need to be broken down into several questions:

1. How precise does the manual adjustment need to be?

2. Is it necessary to read the displacement value?

3. Is it necessary to return to the previous position?

4. Is repeatability of positioning a concern?

5. Is a play permitted during reverse adjustment?"

Step 7

Multi-axis and Mechanical Structure Design

The parameter s of a single axis cannot be directly equated with the system parameters resulting from the combination of the X, Y and Z axes

When multiple single-axis units are stacked to form an XYZ configuration, one cannot simply assume that the performance of the entire system is equal to the specifications of each individual axis, as stacking increases the structural height, weight and moment.

Once multiple axes have been stacked, the following factors must be reconsidered:

The total weight borne by the lower slide;

  • 1. The centre of gravity of the upper platform;
  • 2. The overall height of the structure;
  • 3. The Z-axis overhang;
  • 4. The position of the rotational axis centre;
  • 5. Whether the handwheel/micrometer is easy to operate;
  • 6. Whether there is any mechanical interference between the lens, camera and light source.